Japan has two nuclear reactors operating as of today with capacity of 2,268 megawatts, or 4.6 percent of the total, according to data compiled by Bloomberg.

Kansai Electric Power Co. (9503) halted the 870-megawatt No. 3 reactor at its Takahama nuclear plant in western Japan today for regular planned maintenance, Yusuke Inoue, a spokesman for the utility said by phone.

Reactors have been closed for maintenance, safety checks and stress tests following the March 11 earthquake and tsunami that caused uranium fuel meltdowns and radiation leaks at Tokyo Electric Power Co.’s Fukushima Dai-Ichi plant. The shutdown of the Takahama No. 3 reactor leaves Kansai Electric, the Japanese utility that relies the most on nuclear generation, with all its atomic power plants offline.

The following table shows the status of the 54 reactors with capacity of 48,960 megawatts operated by Japanese power companies. Capacity figures are in megawatts.

COMPANY
UNIT  CAPACITY  STATUS
----------------------------------------------------------------
----------------------------------------------------------------

Hokkaido Electric Power Co.
Tomari
No. 1   579     Shutdown for maintenance. Restart not decided
No. 2   579     Shutdown for maintenance. Restart not decided
No. 3   912     Running. Maintenance shutdown due by late April

Tohoku Electric Power Co.
Onagawa
No. 1   524     Shutdown after quake, tsunami
No. 2   825     Shutdown before quake, tsunami
No. 3   825     Shutdown after quake, tsunami
Higashidori
No. 1   1,100   Shutdown before quake, tsunami

Tokyo Electric Power Co.
Fukushima Dai-Ichi
No. 1   460     Core meltdown after quake, tsunami
No. 2   784     Core meltdown after quake, tsunami
No. 3   784     Core meltdown after quake, tsunami
No. 4   784     Reactor building damaged after quake, tsunami
No. 5   784     Shutdown before quake, tsunami
No. 6   1,100   Shutdown before quake, tsunami
Fukushima Dai-Ni
No. 1   1,100   Shutdown after quake, tsunami
No. 2   1,100   Shutdown after quake, tsunami
No. 3   1,100   Shutdown after quake, tsunami
No. 4   1,100   Shutdown after quake, tsunami
Kashiwazaki Kariwa
No. 1   1,100   Shutdown for maintenance. Restart not decided
No. 2   1,100   Shutdown after 2007 quake
No. 3   1,100   Shutdown after 2007 quake
No. 4   1,100   Shutdown after 2007 quake
No. 5   1,100   Shutdown for maintenance. Restart not decided
No. 6   1,356   Running. Maintenance to start on March 26
No. 7   1,356   Shutdown for maintenance. Restart not decided

Chubu Electric Power Co.
Hamaoka
No. 3   1,100   Shutdown to strengthen quake/tsunami defenses
No. 4   1,137   Shutdown to strengthen quake/tsunami defenses
No. 5   1,380   Shutdown to strengthen quake/tsunami defenses

Hokuriku Electric Power Co.
Shika
No. 1    540    Shutdown due to malfunction. Restart not decided
No. 2    1,206  Shutdown for maintenance. Restart delayed

Kansai Electric Power Co.
Mihama
No. 1    340    Shutdown for maintenance. Restart not decided
No. 2    500    Shutdown due to malfunction. Restart not decided
No. 3    826    Shutdown for maintenance. Restart not decided
Ohi
No. 1    1,175  Shutdown due to malfunction
No. 2    1,175  Shutdown for maintenance. Restart not decided
No. 3    1,180  Shutdown for maintenance. Restart not decided
No. 4    1,180  Shutdown for maintenance. Restart not decided
Takahama
No. 1    826    Shutdown for maintenance. Restart not decided
No. 2    826    Shutdown for maintenance. Restart not decided
No. 3    870    Shutdown for maintenance. Restart not decided
No. 4    870    Shutdown for maintenance. Restart not decided

Chugoku Electric Power Co.
Shimane
No. 1    460    Shutdown for maintenance. Restart not decided
No. 2    820    Shutdown for maintenance. Restart not decided

Shikoku Electric Power Co.
Ikata
No. 1    566    Shutdown for maintenance. Restart not decided
No. 2    566    Shutdown for maintenance. Restart not decided
No. 3    890    Shutdown. Restart delayed

Kyushu Electric Power Co.
Genkai
No. 1    559    Shutdown for maintenance. Restart not decided
No. 2    559    Shutdown for maintenance. Restart delayed
No. 3    1,180  Shutdown for maintenance. Restart delayed
No. 4    1,180  Shutdown for maintenance. Restart not decided
Sendai
No. 1    890    Shutdown for maintenance. Restart not decided
No. 2    890    Shutdown for maintenance. Restart not decided

Japan Atomic Power Co.
Tsuruga
No. 1    357    Shutdown for maintenance through late-February
No. 2    1,160  Shutdown (radiation leak). Maintenance to Dec.
Tokai Dai-Ni
No. 1    1,100  Damaged in March earthquake and tsunami
-----------------------------------------------------------

Sources: Hokkaido Electric, Tohoku Electric, Tokyo Electric, Chubu Electric, Hokuriku Electric, Kansai Electric, Chugoku Electric, Shikoku Electric, Kyushu Electric, Japan Atomic Power.